en

Buyer guides

Digital Building Directory Kiosks: Spec, Content and Cost

Specify a digital building directory: position and format, touch or plain display, tenant data, viewing distance, network and the real cost lines.

By VISIONIX Display TeamDisplay selection and project supportPublished9 min read
Directory display in an office building lobby

A lobby directory is a data product, not a screen

A digital building directory replaces the printed tenant board in a lobby. It lists companies, floors and suite numbers, shows where the visitor is standing, and helps them reach the right door. The screen is the visible part; the tenant list and the floor map behind it decide whether the directory works.

That difference matters at procurement. A directory project is bought as hardware but judged as information. If nobody owns the listing, the screen will be wrong within a quarter, and a wrong directory is worse than the printed board it replaced, because visitors trust it.

The three jobs a directory has to do

Before comparing sizes, write down what the visitor has to achieve at that spot. A directory in a single-tenant headquarters is a welcome board; a directory in a thirty-tenant tower is a search tool. The same 55-inch panel serves both, but the content and the software do not.

  • Identify: the visitor finds a company, department or person by name, floor or category.
  • Locate: the screen shows where the visitor is standing and which way the destination lies.
  • Route: the visitor leaves with a simple instruction — lift bank, floor, turn left after the barrier — not a floor plan to interpret.

If a project cannot describe those three outcomes in one sentence each, the screen count and the software licence are being discussed too early. Fix the outcomes first, then the format follows.

Choose the format from the position, not the other way round

Directory screens are specified by where they stand. A visitor reading a lobby wall is two to four metres away and standing still; a visitor at a free-standing kiosk is within arm's reach and often in a hurry. Distance and posture decide the size, the orientation and whether touch is worth paying for.

PositionFormatTypical sizeReading distanceConfirm before ordering
Entrance or main lobby wallPortrait wall display or recessed panel49–55 inch2–4 mWall material, recess depth, power and data route
Free-standing lobby kioskPortrait floor kiosk, touch optional43–55 inch1–2 mFootprint, base fixing, cable exit, cleaning route
Lift lobby or floor landingPortrait wall display or room sign21.5–43 inch1–2 mSightline from the lift doors, fixing method, floor list per landing
Reception counterSmall landscape or portrait screen21.5–32 inchUnder 1.5 mCounter depth, queue position, staff access
Campus or multi-building entranceLarge portrait kiosk or landscape wall65–86 inch4–8 mBuilding numbering, cross-building map, transport links

The size ranges follow the same distance logic used across our display range: 21.5–43 inch for one to two metres, 43–55 inch for two to four metres, and 65–86 inch where people read from four to eight metres. For text-heavy listings, the practical starting point is 1.5–2 times the screen height, then test the real artwork at the real distance instead of trusting a formula.

Portrait is the usual choice for a directory because tenant lists grow downwards. Portrait support is model-specific, so confirm the panel orientation, bracket and content safe area for the exact model rather than assuming the screen rotates.

Touch screen or a plain display?

Most office lobbies do not need touch. An alphabetical or floor-ordered listing is read faster than a search box is typed, it serves several visitors at once, and there is no glass to smudge or fail. Touch earns its place when the list cannot fit on one screen — large campuses, mixed-use towers, hospitals with many departments — or when the same unit must also show wayfinding routes.

If touch is required, the layer choice matters more than the panel: capacitive glass reads like a phone and survives cleaning, while infrared frames tolerate gloves and heavy use but add a visible frame and a deeper installation. We cover the trade-off in the touch layer guide, so decide the technology before the enclosure drawing is fixed.

Where directory projects fail: the tenant list

In a multi-tenant building the listing changes every time a lease starts or ends. The screen does not generate that information; it renders whatever the building gives it. Before the hardware is ordered, the project needs one named owner for the list, one place where the source of truth lives, and one approval step before a change goes live.

  • Source: is the tenant list a spreadsheet, a property-management database or a directory service? Who can edit it?
  • Change process: how quickly must a new tenant appear after handover — the same day, or at the next monthly update?
  • Approval: who signs off a name, logo, floor number and the multi-language version before publication?
  • Fallback: if the data feed stops, what does the screen show — the last good list, or a static floor board?
  • Records: does the building need a list of who is displayed, for privacy or leasing reasons?

One practical rule: keep evergreen data (tenant names, floors, map) separate from time-sensitive notices (works, events, temporary closures). They have different owners, and mixing them means an emergency notice edit also risks the tenant list.

Designing a listing people can read at 2–4 m

A directory layout has one job: let a stranger find a name in a few seconds. That argues for short lines, strong contrast and a clear order — by floor first, alphabetically within the floor, or grouped by category in mixed-use buildings. Long logos and decorative backgrounds slow the scan down.

Map orientation is the detail most often wrong. A floor plan must be drawn as the visitor faces it, with "you are here" at the bottom. A plan rotated ninety degrees from the physical route creates more confusion than a plain text list, and it is not fixed by adding an arrow.

Keep critical text out of the screen's outer edge, leave one line for the floor and one for the suite number, and test the final artwork on the actual panel at the actual distance. Indoor panels in our range typically run 250–700 cd/m²; in a bright glass lobby, place the screen away from direct sun rather than pushing brightness to the maximum.

Player, network and building IT

A directory is an online device in a lobby, so IT will ask questions before facilities approve it. Plan the answers early: which network and VLAN the player sits on, whether it can reach the content server, who patches it, and what it does when the network is down.

Design for the offline case. The player should hold the last published listing locally, so a failed uplink leaves a correct but static directory instead of a blank screen. A lobby screen that shows an error page is worse than no screen, because visitors queue at reception to ask for directions.

Keep update rights narrow. The building IT team may own the network, facilities may own the screen, and leasing may own the tenant data; the directory only works when those three agree on who presses publish. Write that down in the handover document, together with the CMS account owner and the renewal date.

Duty cycle, cleaning and service access

A lobby directory runs longer than an office monitor and is touched, wiped and leaned on by the public. Specify commercial-grade panels for continuous operation, confirm the duty cycle in writing, and choose an enclosure finish that survives daily cleaning rather than a finish that only looks right on the render.

Service access is part of the design. A floor kiosk needs a lockable compartment for the player, a cable route that cannot be unplugged by a visitor, and enough clearance to open the panel without moving furniture. Wall and recessed units need a bracket that allows the screen to come forward or off without cutting the wall.

For a building with several entrances, keep one spare player and one spare panel of the same size on site. Swapping a unit is a maintenance task; waiting for a warranty shipment turns a single failure into a lobby without a directory for weeks.

What drives the cost of a directory project

Directory budgets are usually compared as a price per screen, which hides most of the project. Two quotes for the same 55-inch portrait kiosk can differ because one includes map artwork and the tenant data setup and the other does not. Ask for the lines below as separate items.

Cost lineWhat sets itWhere it is often missed
Panel and formatSize, brightness, portrait support, duty cyclePortrait rating and continuous operation assumed, not quoted
Touch layerCapacitive or infrared, size, glassVandal protection and cleaning procedure
Enclosure and finishStandard cabinet or bespoke cladding, recess, brandingRecess depth, wall reinforcement, fire-rated wall details
Map artwork and data setupNumber of floors, buildings, languages, tenant countDrawing the plans and cleaning the tenant list before go-live
Software licenceSeats, screens, hosting, support levelRenewal date and who owns the account
Installation and commissioningSite access hours, lift booking, cable route, testingOut-of-hours work in an occupied lobby
Spares and serviceSpare player, spare panel, response timeWho physically swaps a failed unit
Portfolio rolloutNumber of buildings, template reuse, per-site dataPer-building data work priced as a copy of the first site

If a quote arrives as a single number, ask which of these lines are included and which are excluded. The answer tells you more about the project than the total does, because the excluded lines are the ones that reappear as change orders after the lobby is finished.

The brief to send before a directory quote

A supplier cannot size a directory from a floor plan alone. The useful brief is short: where each screen stands, how far the visitor reads from, how many tenants and floors are listed, how many languages are needed, and who updates the list.

  • Position photos and dimensions for every proposed screen, with the visitor's standing point marked.
  • Tenant count, floors and buildings covered; whether the list is one per entrance or shared.
  • Touch or non-touch, and whether floor maps and routes are required at launch.
  • Network availability at each position, and the building IT contact who approves it.
  • Languages, content owner, approval flow and the go-live date.
  • Quantity per model, destination country and packing requirements.

Send those six items and the reply can be a configuration with sizes, quantities and the lines still to be confirmed — instead of a price for a screen that may not fit the wall, the sightline or the tenant list.

Next step

Send the site photos, dimensions and content type. We will reply with a configuration and a model list using the checks in this guide.

Get a Quote

Frequently asked questions

Frequently asked questions

How many directory screens does one building need?

Count decision points, not entrances. Visitors need confirmation at the main entrance, at lift lobbies and where corridors split. Walk the route yourself and mark every point where someone could turn the wrong way; those are the positions worth a screen.

Do we need a touch kiosk or is a wall display enough?

A wall display is enough when the whole tenant list fits on one readable screen. Touch pays off when the list spans several floors or buildings, when visitors must search by name, or when the same unit shows floor maps and routes.

Who updates the tenant list when a company moves out?

The building, not the display supplier. Name one owner in the property or leasing team, keep a single source of truth, and define how fast a change must appear. The supplier configures the playback and the software account; it does not know who signed the lease.

Can the directory show floor maps and a you-are-here marker?

Yes, if the floor plans are supplied as editable artwork and the software supports a map layer. Draw each plan as the visitor faces it, place the marker at the bottom, and avoid rotating the map between floors; a consistent orientation matters more than a detailed drawing.

What brightness suits a glass lobby entrance?

Indoor panels are typically 250–700 cd/m². In a glazed lobby, position the screen out of direct sun and test the reflection from the visitor's standing point at midday. If the screen must face the glass, specify a matte surface and confirm the brightness on site rather than on a datasheet.

Can one template serve several buildings?

The layout can, the data cannot. Reuse the design and the playlist structure across a portfolio, but treat each building's tenant list, floor plans and languages as its own data task. Budgets that assume a copy-paste rollout usually discover the difference after the first two buildings.

Continue reading

Keep reading.

All articles

Need a specification reviewed?

Send the draft specification or the site photos. We will mark the values that need confirmation before you issue the purchase order.

Ask for a review
Get a QuoteWhatsApp